The most frequest question asked by contractors and home owners alike is: Do you have any energy saving results. The answer is YES! Four project homes have been completed in the past year and have been evaluated during this current heating season. These homes are in the Cold climate of Idaho. The results are compelling. The attached files are available for you to download and make part of a presentation folio.

First the two homes that are un occupied. This means that the maintanence temperatures are usually lower and there is no "make up" heating from normal living traffic.

Actual thermal performance of two buildings using Radiant Barrier
Building: Kavanagh Residence, Golden Eagle  
Square Feet 9400 Gas Rate/Therm $1.07
*
Month Gas Bill Heating Cost F difference Heating$/SF/mo BTU's/SF/Month BTU's/SF/Hr. BTU's/SF/F/Day
November 430 344 37 $0.037 3,410.60 4.737 3.073
December 702 413 46.5 $0.044 4,092.72 5.684 2.934
January 689 416 47 $0.044 4,126.83 5.732 2.927
Note: 3,6,9 days of Snow Melt, Building at 65F, Not Occupied
Building: Turner Residence    
Square Feet 8100 Gas Rate/Therm $1.07
Month Gas Bill Heating Cost F Difference Heating$/SF/mo BTU's/SF/Mo BTU's/SF/Hr. BTU's/SF/F/Day
November 411 329 37 $0.041 3,783.09 5.254 3.408
December 691 441 49.5 $0.054 5,069.35 7.041 3.414
January 818 411 47 $0.051 4,728.87 6.568 3.354
Note: 3,6,9 Days Snow Melt, Building at 70F, Occupied 10 days in Dec.; 4 days in January
Notes: RESCheck assumes 25+ BTU's/SF averaged for a heating season 
The typical Actual heat used compared to what DOE's RESCheck expected is  22.72%
* This col. Is a check .. The numbers should be close if the model is acting properly!
Updated: 2/14/06

 

 

 

Unoccupied Homes PDF click here

Test case Two:

Thes two homes are occupied and demonstrate compelling results with normal living temperatures and normal traffic, dogs and all!

Thermal Performance of two Occupied Buildings using Radiant Barrier
Building: Griffen Ranch Residence  
Square Feet 3000 Gas Rate/Therm $1.07
*
Month Gas Bill Heating Cost F difference Heating$/SF/mo BTU's/SF/Month BTU's/SF/Hr. BTU's/SF/F/Day
November 202 167 41 $0.056 5,187.95 7.205 4.218
December 295 245 59 $0.082 7,611.06 10.571 4.300
January 270 225 53 $0.075 6,989.75 9.708 4.396
Ranch style, Unconditioned Craw, single floor plan
Building: Timberline  Residence    
Square Feet 3000 Gas Rate/Therm $1.07
Month Gas Bill Heating Cost F Difference Heating$/SF/mo BTU's/SF/Mo BTU's/SF/Hr. BTU's/SF/F/Day
November 300 230 53 $0.077 7,145.08 9.924 4.494
December 369 299 66 $0.100 9,288.60 12.901 4.691
January 374 304 67 $0.101 9,443.93 13.117 4.698
Two story, 1800SF 28Ft. High cathedral ceilings, garage heated, over unconditioned crawl
Notes: RESCheck assumes 32+ BTU's/SF averaged for a heating season 
The typical Actual heat used compared to what DOE's RESCheck expected is  31.72%
* This col. Is a check .. The numbers should be close if the model is acting properly!
Updated: 3/9/2006

Occupied Homes
 

Foil 101 | About Us | Services | Products | Site Map | Feeling is believing! | California 2005 Building Standards | Vapor, Take Control | Fight Fire With Foil | R-Values: 20% of the Problem | Contact US | Radiant Barrier, Reflective Insulation, Utility Bills and Energy! | Black Globe Effect | The press and media reports